SPECIFICATION
AMBIENT TEMPERATURE:-40 OC TO 70 OC OPERATING PARAMETER: Minimum operating voltage 14 V DC Minimum operating current 14 mA Minimum operating power 0.2 W
SPECIFICATION
Ex ia IIC, T6 Inductance : 0 Capacitance : 40 Pf Orifice: 1.2, 1.6, 1.8, 2.5, 3 Pressure: 0 - 20 bar
Enclosure:
1. General Purpose Flying lead / Plug-in 2. Weather-Proof: Flying lead & Plug in type, Terminal Box as per IS 13947 3. Explosion-Proof with Junction box as per IS 2148 group I, IIA, IIB and IIC 4. Explosion-Proof with Junction box as per ATEX, INMETRO, CE and UL (in process) available.
FEATURES
1. Aluminum / Stainless Steel cast enclosure. 2. Interchangeable to weather proof & explosion proof 3. Solenoid size 14. 4. Response on time < 1.5 sec. 5. Compatible to most available barrier. 6. Dual protection Ex ia & Ex d 7. Suitable to operate any of the valve having Solenoid size 14. (Except 30308, #0310, 30318)
Entity Parameter
| Voltage VDC | 30 | 28 | 24 | 15 | | Current mA | 90 | 110 | 170 | 300 | | Power | 1.2W |
Certification :
ATEX, INMETRO, INDIAN: CCOE, DGMS, BIS.
Rotex has achieved ISO 9001:2000 by TUV and approvals like ATEX, PED, INMETRO, UL, CCOE, CMRI and Bureau of business standards for its explosion proof application for solenoid valves and limit switches. Also Rotex conforms to some of the highest design standards in India and the world, including: En, ISO, ANSI, ASTM, BIS, PIN, NSCE AND IEEE.
Flameproof testing as per IS : 2148 - 2004 (IEC 60079-1/2001) and weatherproof testing as per IS : 12063-1987 for IP-67 of your enclosure for Flameproof cum Weatherproof Limit Switch Housing, in cast aluminum alloy construction, designated by Model : DNLE for use in Gas Group : IIC and Zone 1.
|